Place of Origin UK
Brand Name MTL
Model Number MTL5514
Product Details
Manufacturer:
MTL
Product No:
MTL5514
Product Type:
DETECTOR INTERFACE
Number Of Channels:
One
Location Of Switch:
Div.1, Group A, Hazardous Location
Input/output Characteristics:
Normal Phase
Country Of Origin:
UK
Shipping Weight:
1KG
Highlight: 

Proximity Detector Interface

,

MTL5514 Switch

,

MTL5514 Detector Interface

Payment & Shipping Terms
Minimum Order Quantity
1
Price
Negotiable
Packaging Details
carton
Delivery Time
on request
Payment Terms
T/T
Supply Ability
100+pc+on stock
Product Description

 

Quick Detail of DETECTOR INTERFACE

 
Number of channels:One
Location of switch:
Zone 0, IIC, T6 hazardous area
Div.1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area, if suitably certified
Div.1, Group A, hazardous location
Hazardous–area inputs:
Inputs conforming to BS EN60947–5–6:2001 standards for
proximity detectors (NAMUR)

Description of DETECTOR INTERFACE

 
The MTL5514-T enables a safe–area load to be controlled, through a relay, by a proximity detector or switch located in a hazardous area. Line faults are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection.
 

Specification of DETECTOR INTERFACE

 

Number of channels One
Location of switch Zone 0, IIC, T6 hazardous area
  Div.1, Group A, hazardous location
  Location of proximity detector
  Zone 0, IIC, T4–6 hazardous area, if suitably certified
  Div.1, Group A, hazardous location
Hazardous–area inputs Inputs conforming to BS EN60947–5–6:2001 standards for
  proximity detectors (NAMUR)
Voltage applied to sensor 7 to 9V dc from 1kΩ ±10%
Input/output characteristics Normal phase
  Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
  Outputs open if input < 1.2mA (> 10kΩ in input circuit)
  Hysteresis: 200µA (650Ω) nominal
Line fault detection (LFD) (when selected)  
  User-selectable via switches on the side of the unit. Line faults
  are indicated by an LED. Line fault relay is energised and channel
  output relay de-energised if input line-fault detected
  Open-circuit alarm on if Iin < 50µA
  Open-circuit alarm off if Iin > 250µA
  Short-circuit alarm on if Rin < 100Ω
  Short-circuit alarm off if Rin > 360Ω
  Note: Resistors must be fitted when using the LFD facility with a contact input
  500Ω to 1kΩ in series with switch
  20kΩ to 25kΩ in parallel with switch
Safe-area output  
  Channel: Single pole relay with changeover contacts
  LFD: Single pole relay with changeover contacts
  Note: reactive loads must be adequately suppressed

 

Feature of DETECTOR INTERFACE

 
·1-channel,
·line fault detection,
·phase reversal
 
MTL5514 Switch / Proximity Detector Interface Normal Phase 0MTL5514 Switch / Proximity Detector Interface Normal Phase 1
MTL5514 Switch / Proximity Detector Interface Normal Phase 2MTL5514 Switch / Proximity Detector Interface Normal Phase 3
 

Our Advantage:

Best possible prices and delivery time

Long time experience in the field

Well trained staff

Own warehouse facilities

Best relationships with branch office of manufacture

Flexible and individual service for you

Cheap and safe forwarder for shipments (air)

 

 

Frequently Asked Questions:

Q: Does your goods are new and original?

A: Yes, they are new and original.

 

Q: How long warranty?

A: One-year warranty.

 

Q: Does any certificates can be provided?

A: Yes, it depends on what product you request, please check details with our sales.

 

Q: Varied payment methods.

A: We adopt T/T, alipay and paypal and Currency in EURO,USD,RMB

 

Q: SHIPPING:

A: We can shipping all over the world.via DHL,UPS,Fedex,TNT and IPS,PDE,BRE,KARAPOST etc.

 

Our Product Range:

Transmitter, Safety barries, Flow meters, Probe, Sensor, Transducer. Valves,Analysis meter, Positioner, Acuator, etc.

MTL5514 Switch / Proximity Detector Interface Normal Phase 4

MTL5514 Switch / Proximity Detector Interface Normal Phase 5

  •  

 

 

Contact Us at Any Time

86-755-26850710
Flat 10, 6/F, Block A, Hi-Tech Ind. Ctr. 5-21 Pak Tin Par St, Tsuen Wan, HK
Send your inquiry directly to us